Journal of Intelligent Material Systems and Structures

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

SAGETRACK

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Google Scholar
Right arrow Articles by Lu, L.-Y.
Right arrow Articles by Lin, G.-L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
First published on June 10, 2008
Journal of Intelligent Material Systems and Structures 2008, doi:10.1177/1045389X08091120


Article

A Theoretical Study on Piezoelectric Smart Isolation System for Seismic Protection of Equipment in Near-fault Areas

Lyan-Ywan Lu1* and Ging-Long Lin2

1 Department of Construction Engineering, National Kaohsiung First University of Science and Technology, 1 University Road, Yenchao, Kaohsiung 824, Taiwan
2 Institute of Engineering Science and Technology, National Kaohsiung First University of Science and Technology, Kaohsiung, Taiwan

* To whom correspondence should be addressed.


   Abstract

In order to enhance the efficiency and safety of seismic isolation for equipment subjected to near-fault earthquakes that usually possess a long-period pulse-like waveform, a semi-active isolation system named piezoelectric smart isolation system (PSIS), composed of a sliding isolation platform and a piezoelectric friction damper (PFD), is proposed in this study. By controlling the embedded piezoelectric actuator with a DC voltage, the friction force of the PFD can be regulated; therefore, the PFD is able to provide a supplemental damping, which is controllable by a predetermined control law, for the PSIS system. In order to evaluate its isolation performance, the seismic responses of the PSIS was simulated numerically, and the isolation performance of the PSIS was also compared with those of a passive and an active isolation system. The results of these comparisons are discussed in this study. The simulation result has shown that the PSIS can prevent both the excessive isolator displacement and equipment acceleration induced by the long-period pulse component of a near-fault earthquake.

Key Words: equipment isolation, seismic isolation, near-fault earthquake, piezoelectric actuator, semi-active control, friction damper, smart structures.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?