| Sign In to gain access to subscriptions and/or personal tools. |
Online Deflection Monitoring System for Dafosi Cable-Stayed BridgeOpto-electronic Engineering Department, Chongqing University, Chongqing 400044, China, zhzhzhyong{at}263.net
Opto-electronic Engineering Department, Chongqing University, Chongqing 400044, China
Opto-electronic Engineering Department, Chongqing University, Chongqing 400044, China
Opto-electronic Engineering Department, Chongqing University, Chongqing 400044, China A health monitoring system was designed and installed on Dafosi Bridge, the largest cable-stayed bridge across the Yangtze River in western China. This article briefly describes an online deflection monitoring system, the most important sensing subsystem of the health monitoring system. It can be divided into two major components, one for measurement, and one for control and data processing. The measurement system itself includes two types of deflection sensors to monitor the lateral displacement of the two towers and the flexural and torsional displacement of the main girder. Sensor outputs are pre-processed locally and sent to the host computer at the management center via the Internet. The system design and implementation are reviewed, and the results of data from two kinds of sensors are presented.
Key Words: cable-stayed bridge health monitoring deflection deflectometer opto-electronic sensor on-line
This version was published on September
1, 2006 Journal of Intelligent Material Systems and Structures, Vol. 17, No. 8-9,
701-707 (2006) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||