Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

SAGETRACK

Sign In to gain access to subscriptions and/or personal tools.
Journal of Intelligent Material Systems and Structures
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Ibuki, R.
Right arrow Articles by Yambe, T.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Design of Plate-type Actuator using SMA Wire for Assistant Artificial Heart Muscle

Ryuta Ibuki

Department of Food, Agricultural and Environmental Sciences, Miyagi University, 2-2-1, Hatadate Taihaku-ku, Sendai 982-0215, Japan, ibuki{at}myu.ac.jp

Shigenao Maruyama

Institute of Fluid Science, Tohoku University, 2-1-1, Katahira, Aoba-ku, Sendai 980-8577, Japan

Atsuki Komiya

Institute of Fluid Science, Tohoku University, 2-1-1, Katahira, Aoba-ku, Sendai 980-8577, Japan

Tomoyuki Yambe

Institute of Development, Aging and Cancer, Tohoku University, 4-1, Seiryo, Aoba-ku, Sendai 980-8575, Japan

A compact thin plate-type actuator using Ti—Ni—Cu shape memory alloy (SMA) wire is proposed and designed for its optimized motion to be applied as an assistant artificial heart muscle. The artificial heart muscle will assist by pushing weakened cardiac muscle that has been damaged by myocardial infarction and has lost its ability to contract. The actuator consists of a SMA wire, 250 µm in diameter, and a leaf spring that acts as a bias spring and cooling plate. The SMA wire is fixed at the end of the leaf spring to transform contraction motion into bending of the actuator. The shape of the actuator is controlled by on/off control of electric current applied via the SMA wire. Repeatable bending and releasing will be utilized for the heart assist application. This repeatable actuator motion will be able to assist up to 120 bpm (heartbeats per minute).

Key Words: actuator • assistant artificial heart muscle • medical application • shape memory alloy.

Journal of Intelligent Material Systems and Structures, Vol. 19, No. 3, 359-365 (2008)
DOI: 10.1177/1045389X07084719


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?