Journal of Intelligent Material Systems and Structures

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

SAGETRACK

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1045389X07082377v1
19/7/827    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Google Scholar
Right arrow Articles by Dugnani, R.
Right arrow Articles by Chang, F.K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
This version was published on July 1, 2008
Journal of Intelligent Material Systems and Structures, Vol. 19, No. 7, 827-835 (2008)
DOI: 10.1177/1045389X07082377

In Vitro Atherosclerotic Plaque Characterization by Acoustic Impedance Monitoring, Part II: Experimentation and Validation

R. Dugnani

Department of Aeronautics and Astronautics, Stanford University, Stanford, CA 94305, USA, rdugnani{at}stanfordalumni.org

F.K. Chang

Department of Aeronautics and Astronautics, Stanford University, Stanford, CA 94305, USA

Although coronary atherosclerosis is the leading cause of hospitalization and death in the United States, at present no effective diagnostic technique is available to effectively characterize atherosclerotic plaque in vivo and in real-time. In `Introduction' of this article, we propose the use of an impedance-based technique to diagnose the presence of atherosclerotic plaque. Both analytical and finite element methods are developed to study the effect of a multi-layer substrate in contact with a sensor on the sensor's electro-mechanical impedance. Also a modified version of the Krimholtz, Leedom, and Matthaei (KLM) model is introduced to design the sensor dimension based on a sensor/plaque configuration. An appropriate fabrication technique for manufacturing a small-scale PZT sensor is also proposed for possible use in small arteries. In section `Analytical Model' of the article, we show that the presence of plaque can be accurately predicted by using the proposed impedance-probing technique on samples of human, atherosclerotic tissues. The presence of atherosclerotic plaque in the samples — as predicted by our technique — is confirmed by a histological examination carried out at the Stanford Histology Research Core Lab. The plaque mechanical properties are approximated based on a modified KLM model describing the sensor-artery system. The properties predicted are found to be consistent with the values reported in the literature. A brief study pertaining to the pressure necessary to achieve an acceptable contact between the PZT sensors and the probed artery is presented in the last section of the article. This work suggests that it is possible to characterize atherosclerotic plaque in real-time using the described impedance-based monitoring technique. One future possible application for this technique could be — for instance — the detection of unstable plaque in arteries prior to percutaneous transmural angioplasty (PTA).

Key Words: atherosclerotic plaque • unstable plaque • plaque diagnostic system • plaque characterization • impedance methods • impedance monitoring.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?