Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

SAGETRACK

Sign In to gain access to subscriptions and/or personal tools.
Journal of Intelligent Material Systems and Structures
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow All Versions of this Article:
1045389X06057538v1
17/8-9/823    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Li, F.
Right arrow Articles by Jiang, Z.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

Design and Analysis of a Biosensor Transducer with Multifunctions

Fenlan Li Zhongwei Jiang*

Department of Mechanical Engineering, Yamaguchi University, Ube 755-8611, Japan

* To whom correspondence should be addressed.


   Abstract

This study deals with the development of a simple and multifunctional piezoelectric transducer, which can detect two or more species at one time. The transducer for testing consists of an aluminum cantilever beam and a piezoceramic patch. A piezoelectric impedance-based measurement technique is proposed for detecting a very small biospecies mass sensitively. Furthermore, two different types of biomembranes are coated on the beam so that they can detect two kinds of species without causing interference with each other. The problem as to how to determine the optimal positions for coating the membranes are investigated in detail by the finite element method (FEM). The numerical simulations showed a good agreement with the experimental results. Further, a concept for the design of a multifunctional transducer is proposed based on the mode function, and its validation is proved experimentally.

Key Words: biosensor, transducer, impedance measurement, cantilever beam, piezoceramic patch, FEM, optimal design

First published on May 17, 2006, doi:10.1177/1045389X06057538

Journal of Intelligent Material Systems and Structures 2006;17:823.

A more recent version of this article appeared on September 1, 2006


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?